2007 Mitsubishi Outlander Problem Reports

Newest 2007 Mitsubishi Outlander Problem Reports

Report A Problem

The heating, ventilation and AC (HVAC) temperature control knob may be hard to turn. Mitsubishi Motors has released a service bulletin out outlining the necessary repairs. Repairs involve installing a new air blend door lever and link, lubing the blend door track, and installing a filter on top of the blower motor housing to prevent entry of dirt and debris. If the temperature control assembly has been damaged it will require replacement also.

The crankshaft position sensor may fail causing a stalling can/or no start condition. Replacing the faulty crankshaft position sensor should correct this condition.

Erratic HVAC blower motor operation may be caused by a failed blower motor and/or blower motor resistor. Our technicians tell us that if the blower motor resistor fails the blower motor should be checked. If the blower motor fails its functional test in should be replaced along with the failed blower motor resistor.