Question: Heater won't blow on 1 thru 4, but will blast on 5

Question

sportell, Amelia, OH, April 08, 2009, 18:20
Profile_thumbnail
 Rookie

Why won't my heater and A/C blow on settings 1 thru 4, but works fine on setting 5. It did not work at all and we changed a fuse...at that point only setting 5 worked on the front blower. The back blowers work just fine on all settings. Any suggestions?

2 Answers
Flag This
  • Answer #1

    Bret Bodas April 08, 2009, 21:30
    Profile_thumbnail
     Master

    This is normally caused by a defective blower motor resistor. Power is routed through the resistor to alter the fan speed for settings # 1-4, then on #5 power is supplied directly to the fan motor.

    Flag This
  • Reply

    Visitor, January 12, 2011, 01:35

    i have the same problem

    Reply
    Flag This
  • Answer #2

    Visitor, March 25, 2010, 19:42

    blower resistor motor, located on the front passanger side side below glove box, easy fix.

    Flag This
  • Reply

    MICHAEL_2, February 12, 2011, 11:22
    Profile_thumbnail
     Rookie

    WOULD IT BE POSSIBLE TO SEND A PHOTO OR DIAGRAM AS TO THE LOCATION OF THE RESISTOR?